Hazardous Locations
Hazardous Locations / Explosive Proof - EEx e & ATEX Approved
Hazardous Locations /Explosive Proof - Multi Hole
Liquid Tight Straight Strain Relief Fittings
PG Threads - Nylon & Nickel Plated Brass
UR, CSA, CE, German Lloyd, EEx e, ATEX, RoHS Approvals

Black Nylon Grey Nylon Nickel Plated Brass

Multi Hole Strain Relief Fitting - Hazardous Locations/Explosive Proof - Black Nylon

Multi Hole Strain Relief Fitting - Hazardous Locations/Explosive Proof - Grey Nylon Multi Hole Strain Relief Fitting - Hazardous Locations/Explosive Proof - Nickel Plated Brass
PART NUMBERS
Black Nylon Multi Hole Fittings
Black
PART NUMBERS
Gray Nylon Multi Hole Fittings
Gray
THREAD TYPE AND SIZE SEAL INSERTS DETAILED INFO
No. of Holes

Diameter of Holes

Part Numbers of Inserts Only  
mm Inches
CD07AP-BX CD07AP-GX PG 7 / 1/4"NPT SOLID PLUG 1.089.0799.19 Click here for more information
CD09A1-BX CD09A1-GX

PG 9
 

4 1.4 .06 1.089.0900.19 Click here for more information
CD09A2-BX CD09A2-GX 2 3.0 .12 1.089.0901.19 Click here for more information
CD09A3-BX CD09A3-GX 5 1.6 .06 1.089.0902.19 Click here for more information
CD09A4-BX CD09A4-GX 2 1.7 .07 1.089.0903.19 Click here for more information
CD09A5-BX CD09A5-GX 10 1.4 .06 1.089.0904.19 Click here for more information
CD09A6-BX CD09A6-GX 6 1.4 .06 1.089.0904.19 Click here for more information
CD09A7-BX CD09A7-GX 3 1.7 .07 1.089.0906.19 Click here for more information
CD09A8-BX CD09A8-GX 4 1.7 .07 1.089.0907.19 Click here for more information
CD09A9-BX CD09A9-GX 4 2.3 .09 1.089.0908.19 Click here for more information
CD09AP-BX CD09AP-GX SOLID PLUG 1.089.0999.19 Click here for more information
CD11A1-BX CD11A1-GX

PG 11

 

2 3.0 .12 1.089.1100.19 Click here for more information
CD11A2-BX CD11A2-GX 3 3.0 .12 1.089.1101.19 Click here for more information
CD11A3-BX CD11A3-GX 2 4.0 .16 1.089.1102.19 Click here for more information
CD11A4-BX CD11A4-GX 3 1.5 .06 1.089.1103.19 Click here for more information
CD11A5-BX CD11A5-GX 4 2.8 .11 1.089.1104.19 Click here for more information
CD11AP-BX CD11AP-GX SOLID PLUG 1.089.1199.19 Click here for more information
CD13A1-BX CD13A1-GX PG 13.5 3 2.0 .08 1.089.1300.19 Click here for more information
CD13A2-BX CD13A2-GX 6 3.0 .12 1.089.1301.19 Click here for more information
CD13A3-BX CD13A3-GX 3 4.0 .16 1.089.1302.19 Click here for more information
CD13A4-BX CD13A4-GX 2 5.0 .20 1.089.1303.19 Click here for more information
CD13A5-BX CD13A5-GX 3 3.0 .12 1.089.1304.19 Click here for more information
CD13A6-BX CD13A6-GX 2 5.2 .20 1.089.1305.19 Click here for more information
CD13A7-BX CD13A7-GX 2 3.8 .15 1.089.1306.19 Click here for more information
CD13A8-BX CD13A8-GX 2 4.2 .17 1.089.1307.19 Click here for more information
CD13A9-BX CD13A9-GX 2 2.5 .10 1.089.1308.19 Click here for more information
CD13AP-BX CD13AP-GX SOLID PLUG 1.089.1399.19 Click here for more information
CD16A1-BX CD16A1-GX

PG 16

 

3 3.0 .12 1.089.1600.19 Click here for more information
CD16A2-BX CD16A2-GX 3 4.0 .16 1.089.1601.19 Click here for more information
CD16A3-BX CD16A3-GX 4 4.0 .16 1.089.1602.19 Click here for more information
CD16A4-BX CD16A4-GX 5 4.0 .16 1.089.1603.19 Click here for more information
CD16A5-BX CD16A5-GX 6 4.0 .16 1.089.1604.19 Click here for more information
CD16A6-BX CD16A6-GX 2 6.0 .24 1.089.1605.19 Click here for more information
CD16A7-BX CD16A7-GX 3 5.6 .22 1.089.1606.19 Click here for more information
CD16A8-BX CD16A8-GX 6 3.0 .12 1.089.1607.19 Click here for more information
CD16A9-BX CD16A9-GX 4 3.0 .12 1.089.1610.19 Click here for more information
CD16A0-BX CD16A0-GX 6 3.8 .15 1.089.1609.19 Click here for more information
CD16AP-BX CD16AP-GX SOLID PLUG 1.089.1699.19 Click here for more information
CD21A1-BX CD21A1-GX

PG 21

 

4 6.0 .24 1.089.2100.19 Click here for more information
CD21A2-BX CD21A2-GX 3 7.0 .28 1.089.2101.19 Click here for more information
CD21A3-BX CD21A3-GX 2 8.0 .31 1.089.2102.19 Click here for more information
CD21A4-BX CD21A4-GX 4 5.0 .20 1.089.2103.19 Click here for more information
CD21A5-BX CD21A5-GX 1 8.0 .31 1.089.2104.19 Click here for more information
CD21A6-BX CD21A6-GX 4 5.2 .20 1.089.2105.19 Click here for more information
CD21A7-BX CD21A7-GX 3 5.2 .20 1.089.2106.19 Click here for more information
CD21A8-BX CD21A8-GX 4 5.2 .20 1.089.2107.19 Click here for more information
CD21A9-BX CD21A9-GX 2 7.4 .29 1.089.2108.19 Click here for more information
CD21AP-BX CD21AP-GX SOLID PLUG 1.089.2199.19 Click here for more information
CD29A1-BX CD29A1-GX PG 29

 
6 6.5 .26 1.089.2900.19 Click here for more information
CD29A2-BX CD29A2-GX 4 9.0 .35 1.089.2901.19 Click here for more information
CD29A3-BX CD29A3-GX 4 9.5 .37 1.089.2902.19 Click here for more information
CD29AP-BX CD29AP-GX SOLID PLUG 1.089.2999.19 Click here for more information
CD36A1-BX CD36A1-GX

PG 36

 

5 9.0 .35 1.089.3600.19 Click here for more information
CD36A2-BX CD36A2-GX 7 9.0 .35 1.089.3601.19 Click here for more information
CD36A3-BX CD36A3-GX 6 8.0 .31 1.089.3602.19 Click here for more information
CD36A4-BX CD36A4-GX 2 15.0 .59 1.089.3603.19 Click here for more information
CD36AP-BX CD36AP-GX SOLIDPLUG 1.089.3600.19 Click here for more information
CD42A1-BX CD42A1-GX PG 42
 
3 14.0 .55 1.089.4203.19 Click here for more information
CD42AP-BX CD42AP-GX SOLID PLUG 1.089.4299.19 Click here for more information
CD48A1-BX CD48A1-GX PG 48

 
8 10.0 .39 1.089.4800.19 Click here for more information
CD48A2-BX CD48A2-GX 6 12.0 .47 1.089.4801.19 Click here for more information
CD48A3-BX CD48A3-GX 3 18.0 .71 1.089.4802.19 Click here for more information
CD48AP-BX CD48AP-GX SOLID PLUG 1.089.4899.19 Click here for more information


Hazardous Locations / Explosive Proof - EEx e & ATEX Approved - MULTI-HOLE - Liquid Tight Straight Strain Relief Fittings

 

IMPORTANT:
Design Parameters: Cable diameter should not be less than 80% of hole diameter and the difference between hole and cable diameter should never exceed .04" (1 mm).The Multi Cable fittings will meet NEMA 4x = IP65 if the design parameters are complied with.
To verify a submersible NEMA 6= IP68 application, the final assembly of cables and fittings must be tested by the customer or submitted at the customer's expense to an independent test lab or for certification.
 
How to Order Non-Listed Parts
Note: To Substitute a different thread type replace the 5th position with the following:
"A" PG Thread,"N" NPT Thread, "M" Metric Thread.

e.g. CD09N1-BX becomes CD09A1-BX. Nickel Plated Brass Strain Relief Fitting
 
  • Substitute "MX" for "BX" e.g. CD09N1-BX becomes CD09N1-MX. Gray Strain Relief Fitting
     
  • Substitute "GX" for "BX" e.g. CD13N2-BX becomes CD13N2-GX.

SPECIAL INTEREST:

For a minimum order of 1,000 pieces any special insert hole configuration is available at no extra cost. For small quantities, we suggest drilling the frozen solid plug insert, using the fitting as a fixture.

 

 
Hazardous Locations / Explosive Proof - EEx e & ATEX ApprovedMulti Hole Inserts

TECHNICAL INFORMATION

NYLON

PRESSURE RATING:
150 PSIG (10 BAR) NEMA 4x, 6 (Submersible) - IP 68
MATERIALS:
Fittings: PA(Nylon) V0 according to UL 94 or Nickel Plated Brass
Seal: Elastomer
 

OPERATING TEMPERATURE

-4 °F to 203 °F (-20 °C to 95 °C)