IMPORTANT: Design Parameters: Cable
diameter should not be less than 80% of hole diameter and the
difference between hole and cable diameter should never exceed
.04" (1 mm).The Multi Cable fittings will meet NEMA 4x = IP65
if the design parameters are complied with.
To verify a submersible NEMA 6= IP68 application, the final
assembly of cables and fittings must be tested by the customer
or submitted at the customer's expense to an independent test
lab or for certification.
How to
Order Non-Listed Parts
Note: To Substitute a different thread
type replace the 5th position with the following: "A"PG Thread,"N"NPT Thread, "M"Metric Thread.
e.g. CD09N1-BX becomes CD09A1-BX.
Nickel Plated Brass Strain Relief Fitting
Substitute "MX" for "BX" e.g. CD09N1-BX
becomes CD09N1-MX. Gray Strain Relief Fitting
Substitute "GX" for "BX" e.g. CD13N2-BX
becomes CD13N2-GX.
SPECIAL INTEREST:
For a minimum order of
1,000 pieces any special insert hole configuration is
available at no extra cost. For small quantities, we suggest
drilling the frozen solid plug insert, using the fitting as
a fixture.
TECHNICAL INFORMATION
NYLON
PRESSURE RATING:
150 PSIG (10 BAR) NEMA 4x, 6 (Submersible) - IP 68
MATERIALS: Fittings: PA(Nylon) V0 according to UL 94 or
Nickel Plated Brass Seal: Elastomer